Just like copper wires, NEC (Nationwide Electric Program code) demands indoor fiber optic cables be noted with their fire and smoking rankings. NEC demands SZ Stranding Line be noted correctly and set up correctly for its designed use.

Based on NEC, a building’s inside area is divided into 3 varieties of parts: plenums, risers and general objective locations.

:: What is a Plenum region?

A Plenum region is actually a developing room employed for air flow or air syndication system. Generally in most structures, the location above a decrease roof or under a elevated floor can be used because the atmosphere come back (supply of atmosphere) for your air cooling. These decrease ceiling and raised flooring will also be where fiber wires are often set up. If these cables were burning, they would give off toxic gases and also the gases could be provided to all of those other building by the air conditioning unit. Consequently, individuals could be injured even though they are a considerable ways through the fire.

:: What is a Riser region?

A Riser region is a floor opening, shaft or duct that runs up and down through one or even more floors

:: What exactly is Basic Purpose area?

All the other region that is certainly not plenum or riser and on the same flooring is a general purpose region.

:: fiber Optic Cable Flame and Cigarette smoking Ranking Marks

OFNP Wires:

OFNP is short for Optical fiber Nonconductive Plenum. OFNP wires have fire-level of resistance and reduced smoke creation qualities. They could be placed in ducts, plenums as well as other areas employed for building air flow. Here is the greatest flame rating fiber cable without any other cable kinds can be used substitutes.

OFCP Wires:

OFCP stands for Optical fiber Conductive Plenum. OFCP wires have the same fire and smoking ranking as Optical Fiber Ribbon Machine but they have a performing armor or central power member which is generally metal. OFCP cables has to be properly grounded at both ends. Consequently, OFCP wires cannot be installed in exactly the same cable holder or conduit as energy wires.

OFNR Wires:

OFNR is short for Optical fiber Nonconductive Riser. OFNR wires are utilized in Riser areas which are developing straight shafts or runs from one floor to another floor. OFNR cables can not be set up in plenum locations because they do not possess the necessary fire and cigarette smoking ranking as Plenum ranked wires. OFNP plenum cables can be used as substitutes for OFNR cables.

OFCR Wires:

OFCR stands for Visual fiber Conductive Riser. OFCR wires have a similar flame ranking qualities as OFNR wires however they have performing armor or main power member which can be generally metal. OFCR wires ought to be correctly grounded at both ends. OFCP wires bring alternatives for OFCR cables. OFCR cables cannot be placed in exactly the same cable containers or conduits as energy cables.

OFNG Cables:

OFNG stands for Optical fiber Nonconductive General-Purpose. These are usually utilized in side to side wiring, single floor programs. OFNG cables can not be used in plenums or risers. OFNP and OFNR cables each can be used as substitutes for Secondary Coating Line.

OFCG Cables:

OFCG stands for Optical fiber Conductive Basic-Purpose. They have the same fire qualities as OFNG wires but they have performing armor or main power associates that is usually steel. OFCG cables lvmwml be correctly grounded at both finishes. They should not be set up in the same cable tray or conduits as energy cables.